產(chǎn)品特點:差分探頭|P7360A Tektronix has created a revolutionary Z-Active probe architecture that sets the industry benchmark for signal fidelity. Tektronix active probe architecture preserves high bandwidth while

P7360A差分探頭|P7360A的詳細資料:

差分探頭|P7360A

差分探頭|P7360A

  • Signal Fidelity
    • >12.5 GHz Bandwidth (P7313, Typical)
    • >8.0 GHz Bandwidth (P7380A, Typical)
    • >6.0 GHz Bandwidth (P7360A, Typical)
    • >4.0 GHz Bandwidth (P7340A, Typical)
  • Extended Linear Dynamic Range
    • 1.25 Vp-p at 5x Attenuation (P7313)
    • 4 Vp-p at 25x Attenuation (P7313)
    • 2 Vp-p at 5x Attenuation (P7380A, P7360A, P7340A)
    • 5 Vp-p at 25x Attenuation (P7380A, P7360A, P7340A)
  • Low Probe Loading
    • DC Input Resistance
      • 100 kΩ Differential
      • 50 kΩ Single Ended
    • AC Loading
      • Zmin >200 Ω out to 10 GHz (P7313)
      • Zmin >290 Ω, 4 GHz to 8 GHz (P7380A, P7360A, P7340A)
  • Versatility
    • Make Differential or Single-ended (Ground-referenced) Measurements*1
    • Solder-down Capability
    • Handheld Probing with Variable Spacing and Compliance
    • Fixtured Probing
  • Interchangeable Tip-Clip™ Assemblies
    • Connect to a Variety of Devices
    • Economical
  • TekConnect® Interface

Applications

  • Examples Include, but are not Limited To:
    • PCI-Express I and II, Serial ATA II, USB 2.0, DDRII, DDRIII, Fireware 1394b, Rambus, XAUI

*1 For details, please see application note 60W-18344-0, “Making Single-ended Measurements with Differential Probes.”

Z-Active™ Probing Architecture Leads the Way for High-speed Probing Applications

Tektronix has created a revolutionary Z-Active probe architecture that sets the industry benchmark for signal fidelity. Tektronix active probe architecture preserves high bandwidth while providing improved connectivity with low loading. The Z-Active architecture is a hybrid approach composed of a distributed attenuator topology feeding an active probe amplifier.

The Z-Active probes use a tiny passive probe tip element that is separate from the amplifier, extending the usable reach of the probe. In traditional active probes, adding this much length can introduce signal fidelity problems. However this architecture maintains high DC input resistance and presents a higher AC impedance than previous probe architectures. It accomplishes this while providing significant length between the probe body and the probe attachment point to the DUT. This architecture provides the best of both worlds: high DC impedance like existing active probes and the stable high-frequency loading of Z0 probes.

Signal Fidelity

You can be confident in the signal fidelity of your measurements because the Z-Active architecture provides:

  • High Bandwidth
  • Excellent Step Response
  • Low Loading
  • High CMRR
  • Extended Linear Dynamic Range

Extended Linear Dynamic Range

Many of today’s logic signals and serial bus signals require the capability to measure up to several volts peak to peak.  These voltage levels may easily be viewed with the Z-Active architecture probes (P7380A, P7360A, and P7340A) with the extended linear dynamic range.  With a 2.0 Vp-p linear dynamic input range at the 5x attenuation setting, you can accuray measure DDR II and III, Firewire 1394b, and PCI-Express I and II signals at reduced noise levels.  In addition the 25x attenuation setting’s linear dynamic input voltage range can be used up to 5.0 Vp-p for accessing even larger signal swings found during transition times.

Connectivity

The Z-Active probe design allows the probe to easily switch between soldered, handheld, or fixtured applications.

This family of probes uses Tip-Clip™ assemblies, an interchangeable probe tip system that enables customers to configure their probe with the optimal tip for their application. These detachable assemblies make it possible to replace a tip for a fraction of the cost formerly associated with such hardware changes. The several lengths and variable spacing of the assemblies provide flexibility for adapting to vias and other test points of differing sizes. With Tektronix Tip-Clip assemblies, Monday’s solder-in probe can become Tuesday’s handheld tool, simply by switching tips.

 

 如果你對P7360A差分探頭|P7360A感興趣,想了解更詳細的產(chǎn)品信息,填寫下表直接與廠家聯(lián)系:

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結(jié)果(填寫阿拉伯數(shù)字),如:三加四=7

滬公網(wǎng)安備 31011402002799號

主站蜘蛛池模板: 国产喷水在线观看| 国产精品区一区二区三| 国产ssss在线观看极品| 亚洲国产精品免费视频| 欧美三级一区| 五月婷婷伊人| 全免费毛片在线播放| 久久无码精品一区二区三区| 亚洲 欧美 日韩在线一区| 国产午夜小视频| 亚欧在线观看| 欧美视频免费看| 国产高清免费不卡观看| 欧美亚洲欧美| 日韩免费视频观看| 欧美第5页| 国产一区二区三区 韩国女主播| 久久91精品国产一区二区| 欧美日韩精品| 波多野结衣乳巨码无在线观看| 香蕉乱码成人久久天堂爱免费| 一区二区三区成人| 性色a v 一区| 精品欧美一区二区三区在线| 120秒免费试看| 国产视频播放| 国产一区二区福利久久| 成人国内精品久久久久影院| 国内精品伊人久久大香线焦| 久久国产精品成人免费| 另类交| a级毛片免费高清视频| 国产麻豆精品| 欧美91精品| 全免费a级毛片免费毛视频| 日韩国产在线观看| 国产第一夜| 国产在线播放一区二区| 亚洲欧美另类第一页| 色综合91久久精品中文字幕| 久久精品国产亚洲精品2020|